Website: www.cdlitong.com.cn
Tel: +86 28 87384336
Fax: +86 28 87313114
E-mail: cdlitong@sina.com
CTO: Robert Yang
Cellphone: +86 13882197191
Address : No.6 Qingjiang South Road 4-2-6 Chengdu Sichuan China
Website: www.cdlitong.com.cn
Tel: +86 28 87384336
Fax: +86 28 87313114
E-mail: cdlitong@sina.com
CTO: Robert Yang
Cellphone: +86 13882197191
Address : No.6 Qingjiang South Road 4-2-6 Chengdu Sichuan China

LT1002B Zirconia probe is to measure a variety of fuel boiler, furnace, annealing furnace, pit furnace, carburizing furnaces, waste incineration furnace, sintering furnace oxygen content of oxygen-line detection of the probe.
LT, China and Canada oxygen probe as a co-production, the core components using the world's leading imported components and structures.
High measurement precision, the signal does not drift, long service life, maintenance-free, corrosion resistance, anti-high water.
Widely used in boiler, furnace, annealing furnace, furnace, pit furnace, carburizing furnaces, waste incineration furnace, sintering furnace, etc.. In energy, metallurgy, cement production, petrochemicals, electronics, welding, paper, glass products manufacturing industry, cigarette manufacturing and other industries need to measure the oxygen can be applied on the industry..
LT1002B oxygen probe particularly suitable for high-temperature heat treatment of high carbon black industry, the environment, comes with a two-way purge function (patent).
LT9003C with carbon-controlled instrument, or any other type of carbon-controlled instrument connections, and with a variety of oxygen sensor can be interchangeable at home and abroad.
No check gas check, in full compliance with Knight curve formula.
LT series of products are modular assembly, replacement parts may at any time without having to replace the entire branch probe.
LT products provide life-long maintenance and technical service support, replacement parts only fees collected.
LT1002B Zirconia probe specifications
Application temperature range
700 -1400 ℃
Probe length
250-1219mm
Installation
3 / 4 ", 1" BSP or NPT
Filter diameter
42 mm with 19mm steel shell type
Electrical connection
Direct plug socket type or airline seat, or explosion-proof
Heater
No
Thermocouple
Model K-type or R-type
Response time
<1 second
Probe head temperature
<130 ℃
Reference gas
With ambient air 50cc/min instrument for the pump
Reference Gas Connection
1 / 4 "pipe (PVC) pipe within the cable
Filter type
No Filter
Calibration Gas Connection
1 / 16 "NPT thread
Weight
0.6Kg plus 0.33Kg / 100mm length
Copyright © Chengdu Li Tong Technology Co., Ltd. ICP: 蜀ICP备09019181号